Important! What You Need To Know About The Role Of Shielding In Control Cables


A shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

A shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 vegades el diàmetre exterior del cable. Copper tape shielded or steel tape armored cable should be at least 12 vegades el diàmetre exterior del cable.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    From Copper to Fiber: The Cable Evolution

    Introduction: El "Lifeline of Civilization" Across Time and Space In 1858, after five heartbreaking failures,…

    3 hours ago

    How to quickly understand what three-phase cable is? Favorite here!

    In the world of industrial and commercial power distribution, three-phase cables play a critical role

    4 days ago

    Tempestes i inundacions! Com protegeixen la potència els cables impermeables?

    Introduction In recent years, heavy rainfall and flooding have become increasingly frequent worldwide, causing severe

    1 month ago

    El paper i els reptes de la indústria del cable en l’economia circular

    Introduction As sustainability becomes a global priority, industries across the spectrum are reevaluating their operations

    3 months ago

    Com pot la indústria del cable afrontar el repte global de la cadena de subministrament?

    The global supply chain is an intricate and essential network that connects manufacturers, distributors, retailers,…

    3 months ago

    L’impacte de l’energia renovable en la demanda de cable

    Introduction The global shift toward renewable energy has become a cornerstone of efforts to combat

    3 months ago