Important! What You Need To Know About The Role Of Shielding In Control Cables


EIN shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

EIN shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 mal dem Außendurchmesser des Kabels. Copper tape shielded or steel tape armored cable should be at least 12 mal dem Außendurchmesser des Kabels.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC-Mantel: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    Stürme und Überschwemmungen! Wie wasserdichte Kabel Strom schützen?

    Einführung in den letzten Jahren, Starke Niederschläge und Überschwemmungen sind weltweit immer häufiger geworden, causing severe

    1 month ago

    Die Rolle und Herausforderungen der Kabelindustrie in der Kreislaufwirtschaft

    Einführung als Nachhaltigkeit wird zu einer globalen Priorität, industries across the spectrum are reevaluating their operations

    3 months ago

    Wie kann die Kabelindustrie die globale Herausforderung der Lieferkette meistern??

    Die globale Lieferkette ist ein kompliziertes und essentielles Netzwerk, das Hersteller verbindet, Händler, Einzelhändler,…

    3 months ago

    Der Einfluss erneuerbarer Energien auf die Kabelnachfrage

    Introduction The global shift toward renewable energy has become a cornerstone of efforts to combat

    3 months ago

    Globale Trendprognose für den Kabelmarkt 2025

    Der globale Kabelmarkt ist ein wesentlicher Bestandteil einer Vielzahl von Branchen, einschließlich Energie, Telekommunikation,…

    3 months ago

    KI und Blockchain: Revolutionierung der Kabelherstellung und -verwaltung

    Die Kabelindustrie, ein Eckpfeiler der globalen Infrastruktur, befindet sich in einem Umbruch. Die…

    3 months ago