Por qué usar un cable HVDC para transmisión de larga distancia?


En un moderno sistema de transmisión de CC, solo el enlace de transmisión es DC, el sistema de generación y el sistema de consumo siguen siendo AC. En el extremo emisor de la línea de transmisión, la alimentación de CA del sistema de CA se envía al rectificador a través del transformador convertidor en la estación convertidora. Que cambia la energía de CA de alto voltaje en energía de CC de alto voltaje y la envía a la línea de transmisión de CC.

The DC power is sent to the inverter in the converter station at the receiving end through the transmission line, which changes the high-voltage DC power into a high-voltage AC power line. And then transmits the power to the AC system through the converter transformer. In the DC transmission system, the inverter can be made to work in rectified or inverted state by controlling the converter.

HVDC Transmission Has Many Advantages Compared To AC Transmission

1. HVDC transmission line is significantly more economical. When transmitting the same power, the wire used in DC transmission lines is only 1/2 a 2/3 of that used in AC transmission. DC transmission line uses a two-wire system and compared with a three-wire system, three-phase AC transmission, under the same conditions of transmission line wire cross-section and current density. If the skin effect is not considered, the transmission line and insulation materials can be saved by about 1/3 of the same electric power.

If skin effect and various losses are taken into account, the cross-sectional area of the wire used to transmit the same power AC is greater than or equal to 1.33 times the cross-sectional area of the wire used for DC transmission. Por lo tanto, the wire used for DC transmission is almost half of that used for AC transmission.

In cable transmission lines, high-voltage DC transmission lines do not generate capacitive currents, while AC transmission lines have capacitive currents, which cause losses. On some special occasions, such as when the transmission line passes through the strait, DC cables must be used.

Due to the coaxial capacitor formed between the cable core and the earth, the no-load capacitive current is extremely considerable in the AC high-voltage transmission line. In the DC transmission line, there is no capacitive current added to the cable because the voltage fluctuation is very small.

3. When DC transmission is used, the AC system at both ends of the line does not need to run synchronously, while AC transmission must run synchronously. When long-distance AC transmission is used, there is a significant difference in the phase of the currents at both ends of the AC transmission system.

These two factors cause the AC system to be unsynchronized and need to be adjusted with a complex and large compensation system and a very comprehensive technology. De lo contrario, a strong loop current may be formed in the equipment and damage the equipment, or cause an outage due to unsynchronized operation.

When DC transmission lines are used to interconnect two AC systems, the AC grid at both ends can operate at their frequency and phase without synchronous adjustment.

4. HVDC power transmission system is easy to control and fast, and the loss in case of failure is smaller than that of AC transmission. If two AC systems are interconnected by AC lines, when a short circuit occurs on one side of the system, the other side has to deliver short-circuit current to the fault side.

Por lo tanto, the ability of the original circuit breakers on both sides of the system to cut off the short-circuit current will be threatened and the circuit breakers need to be replaced. If the two AC systems are interconnected by a DC transmission line. The circuit power can be adjusted quickly and easily due to the use of silicon-controlled devices, the short-circuit current delivered by the DC transmission line to the short-circuited AC system is not large. And the short-circuit current of the fault side AC system is almost the same as when there is no interconnection. Por lo tanto, it is not necessary to replace the original switch and current-carrying equipment on both sides.

5. In the HVDC transmission project, each pole is independently regulated and works without influence from each other.

Por lo tanto, when one pole fails, only the faulty pole needs to be shut down and the other pole can still deliver at least 50% of the power. Sin embargo, in an AC transmission line, a permanent fault in any phase must result in a complete line outage.

zmswacables

Recent Posts

Aterrizaje del cable submarino Africa-1 en Ras Ghareb, Egipto

The construction of global communication networks has entered a new era, particularly with the deployment

4 days ago

Tipos y aplicaciones de cables en ingeniería eléctrica

Cables are an indispensable component in electrical engineering, playing critical roles across modern society, de…

1 week ago

La UE amplía su apoyo energético a Ucrania y Moldavia

As winter approaches, energy demand across Europe is rising, and the European Union (EU) is

1 week ago

Fuerte tendencia de demanda para el mercado de fibra óptica médica en Europa

El mercado europeo de fibra óptica médica está preparado para un fuerte crecimiento, driven by the growing

2 weeks ago

2024 Análisis del Precio Internacional del Cobre y 2025 Pronóstico

The international copper price in 2024 has shown a fluctuating upward trend, driven by multiple

2 weeks ago

¿Qué son los cables resistentes a los hidrocarburos?? ¿En qué aplicaciones se pueden utilizar??

Hydrocarbon-resistant cables are essential in environments exposed to various hydrocarbon substances like oils, fuels, y…

3 weeks ago