Information

Important! Ce que vous devez savoir sur le rôle du blindage dans les câbles de commande


UN shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, résistance à l'usure, acid and alkali resistance, resistance to various corrosive gases, résistance au vieillissement, and non-combustibility.

UN shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diamètre du câble. Fluoroplastic insulated and sheathed cables should be at least 8 fois le diamètre extérieur du câble. Copper tape shielded or steel tape armored cable should be at least 12 fois le diamètre extérieur du câble.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    câbles zmswac

    Recent Posts

    Atterrissage du câble sous-marin Africa-1 à Ras Ghareb, Egypte

    La construction de réseaux de communication mondiaux est entrée dans une nouvelle ère, particularly with the deployment

    4 days ago

    Types et applications de câbles en génie électrique

    Cables are an indispensable component in electrical engineering, playing critical roles across modern society, de…

    1 week ago

    L’UE étend son soutien énergétique à l’Ukraine et à la Moldavie

    As winter approaches, energy demand across Europe is rising, and the European Union (EU) is

    1 week ago

    Forte tendance de la demande pour le marché de la fibre optique médicale en Europe

    The European medical fiber optics market is poised for strong growth, driven by the growing

    2 weeks ago

    2024 Analyse des prix internationaux du cuivre et 2025 Prévision

    Le prix international du cuivre en 2024 a montré une tendance à la hausse fluctuante, driven by multiple

    2 weeks ago

    Que sont les câbles résistants aux hydrocarbures? Dans quelles applications peuvent-ils être utilisés?

    Hydrocarbon-resistant cables are essential in environments exposed to various hydrocarbon substances like oils, fuels, et…

    3 weeks ago