UN shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, résistance à l'usure, acid and alkali resistance, resistance to various corrosive gases, résistance au vieillissement, and non-combustibility.
UN shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.
The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.
The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.
They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.
Product characteristics of shielded control cables.
(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diamètre du câble. Fluoroplastic insulated and sheathed cables should be at least 8 fois le diamètre extérieur du câble. Copper tape shielded or steel tape armored cable should be at least 12 fois le diamètre extérieur du câble.
(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.
(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).
La construction de réseaux de communication mondiaux est entrée dans une nouvelle ère, particularly with the deployment…
Cables are an indispensable component in electrical engineering, playing critical roles across modern society, de…
As winter approaches, energy demand across Europe is rising, and the European Union (EU) is…
The European medical fiber optics market is poised for strong growth, driven by the growing…
Le prix international du cuivre en 2024 a montré une tendance à la hausse fluctuante, driven by multiple…
Hydrocarbon-resistant cables are essential in environments exposed to various hydrocarbon substances like oils, fuels, et…