Ba da labari

Aluminum Conductor Composite Core Cable (ACCC) Advantage Introduction


A halin yanzu, overhead cables are used to transport electricity over long distances. Conventional cables are mostly aluminum conductor steel reinforced (Na acsr). Since the 1990s, carbon fiber composite cores (aluminum conductor composite core) have been used as the core bar of cables. ACCC has the following advantages over traditional conductors.

1. High strength and lightweight.

The tensile strength of ordinary steel wire is 1240~1410MPa, while the carbon fiber composite core of the ACCC conductor is twice the former, and its specific gravity is only 1/4 of steel. The weight per unit length of ACCC conductors of the same specification is 10%~20% lighter than conventional ACSR conductors. This allows the tower span of overhead cable to grow, reducing the number of towers by about 16% while reducing the footprint.

2. High conductivity and low transmission loss.

Under the same outer diameter, the cross-sectional area of ACCC’s aluminum strand is 1.29 times that of conventional wires. Saboda haka, the load capacity is increased by about 29%. Because ACCC wire does not have the magnetic loss caused by the wire material and the resistance heat effect. Bugu da kari, it has a lower operating temperature for the same load, which reduces transmission losses by about 6%. Kuma, because ACCC uses trapezoidal aluminum wire, its appearance is smoother than ACSR’s round aluminum wire. The surface roughness coefficient is improved, thus increasing the corona onset voltage of the wire and reducing the corona loss.

3. Low arc sag, reducing sag by more than twice.

ACCC wire has significantly low relaxation characteristics compared to conventional wire. Under high-temperature conditions, the arc sag is less than 12% of steel-core aluminum-stranded wire. It can effectively reduce the insulation space of the overhead line corridor, improve the safety and reliability of the wire operation.

4. Juriya juriya.

ACSR’s aluminum wire and steel core due to long-term exposure to the air. The surrounding environment will corrode the metal material, thus reducing the strength of the wire and affecting the life of the wire. Carbon fiber composite core does not rust, juriya juriya, overcoming the corrosion of galvanized steel stranded wire core. And it also avoids the electrochemical corrosion problem between the aluminum wire and galvanized steel wire when the conductor is energized. Better solve the aging problem of long-term operation of the wire, the service life is higher than the ordinary wire twice.

    zmswacables

    Recent Posts

    Makomar makamashi mai sabuntawa: Abubuwa & Firtsi

    Kamar yadda makamashi mai sabuntawa ya ci gaba da samun lokacinta, its future will be shaped not just by

    5 months ago

    An sabunta makamashi mai sabuntawa: Iri, Fa'idodi, da kuma manyan kalubale

    Ni. Gabatarwa a cikin wata duniya suna fuskantar kalubalen zagayowar canjin yanayi da kuma rashin ƙarfi,…

    5 months ago

    Jagora zuwa Zabin Noma da Gyarawa

    3. Yadda za a zabi kebul na dama don aikace-aikacen gona 3.1 Select Cable Type Based

    6 months ago

    Jagorar da Bautar Aikin gona: Amfani da manyan fasali

    An kori ta na duniya ta zamani ta zamani, agricultural production is rapidly transforming from traditional

    6 months ago

    Haɓaka nawa tare da ɗakunan ma'adinai na dama

    Kamar yadda masana'antar ma'adinai ta duniya ta ci gaba da fadada, mining cables have emerged as the critical

    7 months ago

    Jagora zuwa aikace-aikacen injiniya na lantarki

    Shigowa da: Muhimmancin injiniyan lantarki da kuma rawar da injin injin ZMS kebul, as

    7 months ago