Importante! Cosa devi sapere sul ruolo della schermatura nei cavi di controllo


UN shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

UN shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 volte il diametro esterno del cavo. Copper tape shielded or steel tape armored cable should be at least 12 volte il diametro esterno del cavo.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    Cos'è Ethernet?

    In today’s interconnected world, Ethernet serves as the backbone of modern networking. Whether you're setting

    5 days ago

    La parte superiore 10 Concetti avanzati di ingegneria elettrica

    Electrical engineering is a complex and dynamic discipline that underpins critical aspects of modern life,…

    1 week ago

    Impatto dell'intelligenza artificiale sull'ingegneria elettrica

    Introduzione Intelligenza Artificiale (AI) ha permeato numerosi settori, processi rivoluzionari, migliorando l’efficienza, and enabling new

    3 weeks ago

    Rimozione dei cavi per telecomunicazioni rivestiti di piombo dal Lago Tahoe

    Lago Tahoe meridionale, California. – In un risultato ambientale rivoluzionario, the League to Save Lake

    3 weeks ago

    Rete intelligente: Guidare il futuro della trasformazione energetica

    Introduzione Le richieste energetiche globali stanno aumentando vertiginosamente insieme alle urgenti richieste di azione per il clima. Reti elettriche tradizionali,…

    3 weeks ago

    Cosa sai sulla costruzione di impianti elettrici?

    Gli impianti elettrici sono la spina dorsale degli edifici moderni, abilitando funzioni essenziali come l’illuminazione, riscaldamento,…

    4 weeks ago