Importante! Cosa devi sapere sul ruolo della schermatura nei cavi di controllo


UN shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

UN shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 volte il diametro esterno del cavo. Copper tape shielded or steel tape armored cable should be at least 12 volte il diametro esterno del cavo.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    300 Billion KHS! The World’s Highest Voltage Transmission Project Sends Out a Big Breakthrough In the Amount of Electricity

    As of 0:00 on October 8, Changji-Guquan ± 1100 kV UHV DC transmission project (hereinafter

    12 hours ago

    The Impact of Dollar Interest Rate Cuts on the Power Industry

    In anni recenti, interest rate decisions made by the Federal Reserve have had significant implications

    1 day ago

    Understanding AAC Cables in Depth

    In modern power transmission systems, cables play a crucial role as the "veins" of the

    2 days ago

    L’OMS della Malesia investe $300 Milioni di sistemi via cavo

    La società malese di costruzione di cavi OMS ha messo da parte $300 million to invest in new cable

    5 days ago

    Qual è la differenza tra il cavo in fibra ottica G652D e altri cavi in ​​fibra??

    I cavi in ​​fibra ottica hanno rivoluzionato la comunicazione, enabling high-speed data transmission over long distances with minimal

    5 days ago

    Cos'è il cavo elettrico intrecciato e quali sono alcune applicazioni comuni?

    Stranded Electric Cable is a versatile and essential type of electrical conductor used in a

    5 days ago