The Role and Difference of Metal Shielding of Medium-voltage Cable


In the power industry, 220 volts and 380 volts are considered to be low voltage, mainly for household electricity. 35,000 volts and above are high voltage, mainly used for power transmission. In between, it is medium voltage. And it is extremely dangerous to touch high-voltage power lines or to carry out live work under the lines.

Thickness of Copper Tape

The nominal thickness of copper tape for shielding single-core cable shall not be less than 0.12mm. The copper wire shielding layer is composed of loosely wound soft copper wires whose surfaces are tightly bound with reverse-wound copper wires or copper tapes.

The average gap between adjacent copper wires is not more than 4mm. The shielding method of copper wire and copper tape winding can structurally improve the shortcomings of the copper tape winding shielding method.

There is neither an oxide layer produced by overlapping copper strips, nor strong bending and hot and cold deformation, and the copper strip winding is not easy to be arched and embedded in the insulating shielding layer.

Cross-section of the Metal Shield

The cross-section of the metal shield directly affects the ability of the cable to withstand short-circuit current in the event of a fault.

If the cross section is too small, the short circuit current can overheat or burn the insulation. Daarom, it is necessary to determine the cross-section of the metal shield according to the fault current capacity. In cables of 10kV and below, when the conductor cross-section exceeds 500, try to use copper wire shielding. If you insist on shielding with copper tape, you need to thicken the thickness of the copper tape.

Depending on the cable laying situation, if it needs to carry a large short-circuit huidig, it is recommended to use copper wire shielding. Daarom, the difference between copper tape shielding and copper wire shielding is the ability to carry short-circuit current. The copper wire is slightly larger (also depends on the effect of the copper wire). Copper tape has a uniform magnetic field and shielding effect.

Hope this article was helpful. Any question about cable products, please contact us.

    ZMSwacables

    Recent Posts

    Toekomst van hernieuwbare energie: Trends & Innovatie

    Terwijl hernieuwbare energie aan kracht blijft, its future will be shaped not just by

    5 months ago

    Hernieuwbare energie uitgelegd: Soorten, Voordelen, en belangrijke uitdagingen

    I. Inleiding in een wereld die wordt geconfronteerd met de dubbele uitdagingen van klimaatverandering en uitputting van hulpbronnen,…

    5 months ago

    Gids voor selectie van landbouwkabel en intelligent onderhoud

    3. Hoe u de juiste kabel kiest voor landbouwtoepassingen 3.1 Select Cable Type Based

    6 months ago

    Landbouwkabelgids: Gebruik en hoofdfuncties

    Gedreven door de wereldwijde golf van agrarische modernisering, agricultural production is rapidly transforming from traditional

    6 months ago

    Boost uw mijn met de juiste mijnkabels

    Terwijl de wereldwijde mijnindustrie blijft uitbreiden, mining cables have emerged as the critical

    7 months ago

    Een gids voor toepassingen voor elektrotechniek

    Invoering: Het belang van elektrotechniek en de rol van elektrotechniek van ZMS -kabel, as

    7 months ago